UV Differential Absorption Spectrometry Gas Analysis System
DOAS-3000 online differential UV spectrum analyzer is used in various high temperature and high humidity or high dust occasions, with optional automatic blowback system, otherwise it needs manual maintenance and cleaning of dust filters.
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
Details
DOAS-3000 System composition: sampling unit, sample gas pretreatment unit, gas analysis unit
Main principle is: the sampling unit collects the flue gas or the measured gas at the site, the pre-processing unit filters the dust, high temperature cooling, electric heat insulation, double-stage high efficiency dehumidification, and controls the temperature and humidity of the measured gas and dust particles in a certain range to make it reach the cleanliness required by the analyzer, and then sends it to the gas analysis unit for detection and analysis, displays the measured gas concentration on the display in real time, and transmits the data signal to the PLC or The data signal is transmitted outward to PLC or computer terminals, and can also be transmitted to the cloud server through wireless GPRS or network, and then the user can read the data from the server, which can realize global network monitoring and analysis. The whole process is automated and does not require human intervention.
DOAS-3000 online differential UV spectrum analyzer is used in various high temperature and high humidity or high dust occasions, with optional automatic blowback system, otherwise it needs manual maintenance and cleaning of dust filters. The whole sampling pipeline has electric heat insulation function, which is conducive to removing water vapor and preventing part of the gas from dissolving in condensate to improve the accuracy of detection and analysis, and the built-in double-stage high-efficiency condensation and dehumidification system can control the dew point of gas stably at 4℃ or 5℃ to meet the humidity control requirements of various principles of analytical instruments for gas.
Parameter
Detection parameters | NO, NO2, SO2, NH3, H2S, O3, benzene, toluene, xylene, etc. Can also be optional Pitot tube detection of flue wind speed, temperature, pressure, flow |
Measuring range | 0-2, 10, 20, 50, 100, 500, 1000, 2000ppm, other ranges can be customized |
Detection principle | UV differential absorption spectrometry (DOAS) |
Sampling temperature | – 40℃ ~800℃ (standard), optional: – 40℃ ~1300℃,-40℃ ~2000℃ |
Sampling humidity | 0 ~ 99% RH |
Host working environment | – 40℃ ~70℃, ≤ 95%RH |
Working mode | On-line continuous work, pump suction and extraction sampling; |
Sampling distance | Standard 30~40 m, optional vacuum pump sampling distance greater than 70 m |
Sampling flow | adjustable, 4 l/min (standard), 10 l/min, optional |
Output signal | 4~20mA, RS485, multi-way passive contact, optional: wireless transmission, network transmission |
Protection level | IP66 outdoor waterproof type, optional explosion-proof type |
Application
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.