SC200 Universal Controller: 100-240 V AC (EU power cord) with two analog flow sensor inputs, MODBUS RS232 & RS485 and two 4-20mA

20 Items sold in last 3 minutes

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

17 People watching this product now!
Category:
Description

One Controller for the Broadest Range of Sensors

The sc200 Universal Controller is the most versatile controller on the market. It allows the use of digital and analog sensors, either alone or in combination, to provide compatibility with the broadest range of sensors. It replaces the Hach sc100 digital and GLI53 analog controllers with advanced features for easier operator use. The sc200 controller can be configured to operate two digital sensor inputs, two analog sensor inputs, or a combination of one digital and one analog input. Customers may add communication modules for a variety of protocols including MODBUS RTU, Profibus DPV1, and HART.

Applications:

  • Municipal Water

Benefits

Maximum Versatility

• Standardized controller eliminates the need for a variety of dedicated controllers
• Multi-channel controller operates either 1 or 2 sensors reducing inventory holding costs, and providing an inexpensive option to add a second sensor at a later time
• “Plug and Play” operation with all Hach digital sensors
• True dual sensor controller provides 4-20 mA outputs to transmit primary and secondary measurement values

Ease of Use

• New display and guided calibration procedures reduce operator error
• Simple, intuitive user interface for navigating both sensor and controller options

Confidence in Results

• Password protected SD card reader offers a simple solution for data download and transfer
• Visual warning system provides critical alerts

One Controller, Numerous Communication Options

Hach offers the largest portfolio sensors and analyzers for water analytics with MODBUS RS232, MODBUS RS485, Profibus® DP, and HART capability.

Broadest Range of Sensors

Use the sc200™ Universal Controller in combination with over 30 different sensor families covering 17 different parameters

Specifications

Relay

Operational Mode Primary or secondary measurement, calculated value (dual channel only) or timer

Technical Attributes

Analog Output Functional Mode Linear, logarithmic, bi-linear, PID
Analog Outputs Two (five with optional expansion module) to isolated current outputs, max 550 Ω , accuracy: ± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range
Operational mode: measurement or calculated value
Communication Modbus RS232/RS485, Profibus
Communication MODBUS RS232 & RS485 and two 4-20mA outputs
Communication Capabilities Modbus RS232/RS485
Conduit Openings 1/2“ NPT Conduit
Dimensions (H x W x D) 144 mm x 144 mm x 181 mm
Display Graphic dot matrix LCD with LED backlighting, transreflective
Display Resolution 240 x 160 pixels
Electrical Certifications EMC
CE compliant for conducted and radiated emissions:
– CISPR 11 (Class A limits)
– EMC Immunity EN 61326-1 (Industrial limits)
Safety
cETLus safety mark for:
– General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
cULus safety mark
– General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Enclosure Rating IP66 / NEMA 4X
Length 181 mm
Manual Languages Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Material Enclosures Polycarbonate
Aluminium (powder coated)
Stainless steel
Mounting Configurations Wall, pole, and panel mounting
Operating Temperature Range -20 – 60 °C at 0 – 95% RH (non-condensing)
Power Options 100-240V AC, EU Power Cord
Power Requirements (Hz) 50 – 60 Hz
Power Requirements (Voltage) 100 – 240 VAC
Power Supply EU power cord, with 2x strain relief’s
Relay Functions Scheduler (timer), alarm, feeder control, event control, pulse width modulation, frequency control, and warning
Security Levels 2 password-protected levels
Sensor Input #1 Analog Flow
Sensor Input #2 Analog Flow
Storage Conditions -20 °C to 70 °C
Weight 1.70 kg
What’s included? Controller, Mounting Hardware, Basic User Manual
Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “SC200 Universal Controller: 100-240 V AC (EU power cord) with two analog flow sensor inputs, MODBUS RS232 & RS485 and two 4-20mA”

Your email address will not be published. Required fields are marked *