LS Series Elevating-type Pulse Vacuum Vertical Autoclave
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
-
valid capacity :60L 80L 100L 120L
-
working pressure:0.22Mpa
-
working temperature :134℃
-
heat average :≤±1℃
-
timer :0-99min
-
Temperature adjust ra :105-134℃
wholesale custom wabi vertical used tabletop steam sterilizer
Characteristics
• 7″ capacitive touch screen, fully automatically controlled, easy to operate on.
• Elevating type door, which is more convenient to place and fetch the objects from the autoclave.
• The whole procedure from water inlet, pulse vacuum, heat, sterilizing, water outlet, exhausting to vacuum drying,
which are all automatically by one-key operation.
• Pulse vacuum, the limit is -0.080Mpa, which ensure the sterilizing more completely.
• Separated steam generator, which is more energy saving by comparing to the normal heating and prevent the
sterilizing objects from been oxidized.
• There are several programs loaded in the autoclaves for different requirement of different objects.
• With PT-TT testing port, easy to run the testing.
• Equipped with Germany SARTORIUS Sterile ventilation filter MIDISART 2000 0.20um, which ensure the air is sterile,
prevent the contamination.
• Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
Technical Data
MODEL | LS-60SV | LS-80SV | LS-100SV | LS-120SV |
---|---|---|---|---|
Technical | ||||
Chamber volume | 60Lφ396×490mm | 80Lφ396×650mm | 100L504×404×502mm | 120L504×404×590mm |
The height after rising | 1310 | 1590 | 1475 | 1565 |
Working pressure | 0.22Mpa | |||
Working temperature | 134℃ | |||
Heat average | ≤±1℃ | |||
Timer range | 0-99min | |||
Temperature adjust range | 105-134℃ | |||
Power | Steam generator:3KWDry blanket:2.4KW/AC220V 50HZ | Steam generator:3.6KWDry blanket:2.4KW/AC220V 50HZ | ||
Overall dimension(mm) | 686×556×913 | 686×556×1035 | 840×600×970 | 840×600×1060 |
Transport dimension(mm) | 789×656×1013 | 786×656×1135 | 940×610×1000 | 940×610×1075 |
G.W/N.W | 210Kg/180Kg | 230Kg/200Kg | 300Kg/270Kg | 325Kg/295Kg |
When using the pressure steam sterilizer, the following requirements should be strictly followed:
1. In order to ensure safe use, ensure that the power cord of the autoclave has a good grounding.
2. The autoclave should be placed in a suitable environment, should be ventilated and dry, and free of inflammable and explosive materials.
3. Do not disassemble the safety valve, the lead seals and screws on the steam release valve, etc.
4. The items stacked in the sterilizer should not exceed 4/5 of the volume, otherwise there will be potential safety hazards.
5. When the sealing ring is attached with oil, it is easy to damage the colloid and cause air leakage, which should be avoided as much as possible.
6. Chemicals that cause explosion or sudden pressure increase in contact with the steam medium cannot be sterilized with a sterilizer.
7. When stacking sterilized items, it should be ensured that enough space is left, and the air outlet holes of the safety valve and the steam release
valve cannot be blocked, so as to ensure the smoothness of the air and ensure safety.
8. The liquid should be filled in a heat-resistant glass bottle for sterilization. The liquid should not exceed 3/4 of the bottle volume. The bottle mouth
should not use perforated rubber or cork stoppers, but cotton gauze stoppers.
9. Do not put items of different types and different sterilization requirements together for sterilization.
10. After the sterilization is over, the steam cannot be released immediately, and the residual gas must be discharged after the pointer of the pressure
gauge returns to zero.
11. The pressure gauge of the autoclave should be calibrated regularly and replaced in time if necessary.
12. Check the safety valve regularly, and replace it immediately when it fails.
13. Always check the sealing of the sealing ring and replace it in time.
14. After the autoclave is used, the water in the container should be removed, and if there is scale on the container or electric heating pipe, it should
also be cleaned to prolong the life.
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.