Horizontal steam sterilizer

1,520.00৳ 

OEM:Available
Sample:Refuse
Port:Nan shaPort,HUANGPU,YANTIAN,SHEKOU
Payment:PayPal,VISA,Western Union,T/T,Other,MasterCard,L/C,D/P,D/A
Place of Origin:China
Shipping:Support Express · Sea freight · Land freight · Air freight
Supply Ability:1000 unit per week

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

Category:
Description
Quick Details
  • valid capacity :
    150L 200L 280L 400L 500L
  • working pressure:
    0.22Mpa
  • Maximum safety pressure:
    0.165Mpa
  • working temperature :
    134℃
  • heat average :
    ≤±2℃
  • Time for sterilization:
    0-60min
  • Time for drying:
    0-60min
  • temperature range :
    40℃-134℃

wholesale custom home large portable rapid steam sterilizer

Use

The horizontal autoclave, which adopte the way of gravity exchange to release the cold air from the chamber

more completely toensure the reliable sterilization.The control system automatically adjust the steam inlet and

outlet according to chambertemperature during sterilizing. This unit is an ideal equipment for clinics,scientific

research institutes and other organizations tosterilize surgical instruments, fabric glassed, and the culture media etc.

High-pressure steam sterilizer is a device that uses saturated pressure steam to sterilize items quickly and reliably.

It is suitable for medical and health, scientific research, agriculture and other units. Autoclave sterilizers are divided

into portable autoclave sterilizers, vertical autoclave sterilizers, and horizontal autoclave sterilizers according to style

and size. It can sterilize medical equipment, dressings, glassware, solution culture medium, etc.

 

Characteristics

• Automatially controlled the sterilizing process, easy to operate.

• With drying function, suitable for the medical dressing drying.

• With overtemperature, overpressure autoprotect.

• The door can not be open until the pressure in the chamber is reduced to 0.027MPa. And the unit can not be started on if the Idoor doesn’t close well.

• The safety valve will be open automatically when the inner pressure over 0.24MPa and the steam would be exhausted the water tank.

• Automatically cut off the power if the waterlack happened, and alarm at the meanwhile.

• The chamber of the sterilizer is made of stainless steel.

 

Technical Data

MODEL WS-150YDA WS-200YDA WS-280YDA WS-400YDA WS-500YDA
Technical Data
Stenilizing chamber volume 150Lφ440×1000 200Lφ515×1000 280Lφ600×1000 400Lφ700×1100 500Lφ700×1300mm
Working pressure 0.22Mpa
Working temperature 134℃
Temperature adjust range 40℃-134℃
Time for sterilization 0-60min
Time for drying 0-60min
Heat average ≤±2℃
Power 9kw/380V 50Hz 9kw/380V 50Hz 12kw/380V 50Hz 18kw/380V 50Hz 18kw/380V 50Hz
Dimension(mm) 1400×600×1300 1400×670×1650 1400×770×1780 1430×880×1830 1800×900×1820
Exerior package dimension(mm) 1550×750×1850 1560×820×1850 1680×920×2100 1600×1050×2100 1850×1050×2100
G.W/N.W 320/240kg 350/260kg 465/365Kg 530/420Kg 580/470Kg

 

Autoclave Sterilizer Time Control:

1. In general, the lower the sterilization temperature, the longer the sterilization time required by the autoclave; the higher the sterilization temperature,

the shorter the sterilization time required by the autoclave. However, the time of pressure steam sterilization should be counted from the time when the

autoclave chamber reaches the required sterilization temperature until the sterilization is completed.

2. Total autoclave time includes:

Thermal penetration time, that is, the time required from reaching the sterilization temperature in the sterilization cabinet to the time when the center

of the sterilized item also reaches the sterilization temperature. The length of time depends on the nature of the items to be sterilized, the size of the package,

the location and the degree of air evacuation in the autoclave and the type of sterilizer.

Sterilization maintenance time, that is, the time required to kill microorganisms, is generally expressed by the time required to kill Thermobacter stearothermophilus

spores. 30 minutes at 115°C, 12 minutes at 121°C, and 2 minutes at 132°C.

3. The safety time is generally half of the maintenance time, and its length depends on the disinfection items. Sterilization of thermally conductive metal equipment

does not require a safe time.

Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “Horizontal steam sterilizer”

Your email address will not be published. Required fields are marked *