3D Shaker

1,520.00৳ 

OEM:Available
Sample:Refuse
Port:Nan shaPort,HUANGPU,YANTIAN,SHEKOU
Payment:PayPal,VISA,Western Union,T/T,Other
Place of Origin:China
Shipping:Support Express · Sea freight · Land freight · Air freight
Supply Ability:1000 unit per day

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

Description
Quick Details
  • Specifications:
    SK-D3309-Pro
  • Certification:
    CE FCC
  • Speed range:
    10-70rpm
  • Tilt angle:
  • Speed display:
    LCD
  • Timer display:
    LCD
  • Motor type:
    DC motor
  • Max. load capacity (with platf:
    5kg

wholesale co2 in incubator for animal cell culture supplier factory of sale

The laboratory shaker, also known as the oscillator incubator, is a multi-purpose biochemical instrument that is used in experiments

that have high requirements on temperature and oscillation frequency, such as bacterial culture, biochemical reactions, fermentation,

enzyme organization and research, etc. . Suitable for plants, biology, microorganisms, genetics, environmental protection, medicine, chemical industry and other fields.

 

Key Features

•   Three-dimensional rocking motion with an angle of 9°

•   Max. load capacity is 5kg with platform

•   Speed range of 10-70rpm

•   Double LCDs for independent display of time and speed

•   Various of platform accessories

 

 Specifications SK-D3309-Pro
Tilt angle
Max. load capacity (with platform) 5kg
Motor type DC motor
Motor input power 40W
Motor output power 24W
Speed range 10-70rpm
Speed display LCD
Timer display LCD
Time settings range 1min-19h59min
Voltage 100-240V,  50/60Hz
Power 50W
Weight 9kg
Permissible ambient temperature and humidity 5-40°C 80%RH
Dimension[W×D×H] 360×430×106mm
Protection class IP21

 

Accessories
Cat. No. P/N Descriptions
18900027 SK330.1 Universal attachment with 4 bars
18900028 SK330.2 Fixing clip attachment
18900040 SK330.3 Lengthways roller attachment
18900155 SK330.5 Dish platform with non-slip mat and fixed string(8 pcs)
18900036 Bar for SK330.1 Universal attachment,black
18900029 SK330.2.1 Fixing clip for flask volume 25 ml
18900030 SK330.2.2 Fixing clip for flask volume 50 ml
18900031 SK330.2.3 Fixing clip for flask volume 100 ml
18900032 SK330.2.4 Fixing clip for flask volume 200/250 ml
18900033 SK330.2.5 Fixing clip for flask volume 500 ml
18900280 Connect sticks for double dishes shaker 1/pK

 

Before buying a laboratory shaker, you first need to understand these 5 most important questions:

1. What is the unit capacity (total weight and total volume) of the shake flask you need?

2. Are there any other included standard accessories?

3. What is the RPM range? What is the increment he can control?

4. What is the temperature and humidity required for the operating environment?

5. If there is programming function, what are its functions?

 

When using a common laboratory shaker, pay attention to the following aspects:

1. Use environment

Please ensure that the indoor temperature range is between 18°C ​​~ 34°C and the relative humidity is up to 90%

2. Positioning

Place the shaker on a surface or workbench capable of supporting the weight of the shaker and all associated parts

3. Parts installation

Installation of the flask clamp is accomplished by securing the base of the clamp to the platform using the correct

type and number of screws.

4. Power supply voltage

Please confirm that the local power supply voltage meets the requirements before use. It is recommended to connect

the device to a dedicated power supply with grounding protection installed.

5. Equipment leveling

Properly level the device by placing a bubble level on the top drive bearing housing

6. Standard operation

When the shaker rotates at high speed, in order to avoid large vibration of the instrument, the culture reagent bottles should

be placed symmetrically on the shaker, and the culture solution of each bottle should be roughly equal. Please fix the sample

firmly on the shaker, and make sure that the sample will not be shaken violently before leaving when the shaker is working.

During the sampling process, if any sample is found to be missing (including the drop of the plug), the main power should be

turned off, and the debris should be removed with tweezers as much as possible. If necessary, some parts should be disassembled

for cleaning. . It is forbidden to put the pipe rack made of plastic foam into the shaker, so as to avoid the foam particles being

sucked into the fan shaft, which will cause the fan to overheat and burn! When removing the sample, turn off the power or set the speed to zero.

7. Maintenance

The surface of the instrument should be scrubbed frequently to keep it clean, and the side of the instrument control box should

be avoided when scrubbing to avoid water dripping into the instrument and damaging the instrument. When the instrument is used

frequently, an appropriate amount of grease should be added every few months, and the fuse box, control elements and fastening screws

of the instrument should be checked regularly for looseness.

Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “3D Shaker”

Your email address will not be published. Required fields are marked *