Products Description
LC16 is a capacitance liquid level sensor especially designed for accurately measuring liquid levels in automobile oil tanks, sealed tankers, truck fuel tanks, locomotive tanks, and oil depots. With no mobile or elastic parts, it offers excellent impact resistance, easy installation, high reliability, precision, and stability. LC16 supports local recalibration of zero and span through two calibration wires. It caters to various applications, measuring levels of gasoline, diesel, water, hydraulic oil, and other non-conductive liquids.
Product Features
- High-quality chip and capacitor components imported from the USA with an high accuracy of 0.5% F.S and a resolution of 0.1mm.
- Corrosion-resistant SUS304 stainless steel housing, and high-quality brass electrodes with no moving parts
- Local two-wire touch calibration supported and RS485 signal enables computer-automated calibration and local calibration with “Zero” and “Full Scale.”
- Customization and high-temperature operation of media up to 200℃.
- Temperature compensation, interference resistance, and digital filtering technology.
Product Specification
Pressure Range | 0-100 mm…1800mm optional | ||
Medium compatible | Diesel, gasoline; water and others liquid is customized | ||
Accuracy | ≤ ±1.0%F.S; ≤ ±0.5%F.S; | ||
Electronic Wire | 3 wires type
but with another two wires for calibration |
3 wires type
but with another two wires for calibration |
4 Wires |
Output | 4-20 mA | 0-5V | RS485 |
Power Supply | 11~33 V dc | 12VDC or 11~33 V dc | 11~33 V dc |
Blind Zone | Standard type is 10 or 15 mm, Min blind is 7 mm by customized. | ||
Stability | Standard: 0.01%F.S/3 years, Max: 0.02%F.S/3years | ||
Medium working Temp. | -30℃ to 85℃ standard type, -40℃~125℃ are customized. | ||
Electrical connection | Fixed cable by stainless steel cap, explosion proof; IP67 | ||
Process connection | G1/2” male, M20*1.5 male, Flanges 2.5”… (by customized) |
Product Dimensions
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.