Features:
★《Chassis/Pharmaceutical Integrated Aluminum Alloy Chassis》Professional design, easy to carry, durable, with complete sets of accessories and finished pharmaceuticals.
★Microcomputer control, digital circuit, program design, LCD display, AC and DC dual-purpose, field flow test.
★Resolution: 0.001, touch button, built-in new generation thermal printer, can print test results.
★Can detect quick-acting nitrogen, quick-acting phosphorus, effective potassium, total nitrogen, total phosphorus, total potassium, organic matter, pH in fertilizers and organic fertilizers (including foliar fertilizers, water-soluble fertilizers, spray fertilizers, etc.), calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, molybdenum and other trace elements and various heavy metals such as lead, chromium, cadmium, mercury, arsenic, nickel, aluminum, fluorine, titanium, selenium.
★Adopt high-brightness LED light source and double dial filter processing technology to ensure the stability of the light source wavelength. Silicon semiconductor is used as the signal receiving system, and the life span is up to 100,000 hours.
★The colorimetric tank adopts a single-channel design, without mechanical displacement and wear, and the optical path test positioning is accurate to ensure the accuracy of the measurement results.
★Adopting high-precision filter technology and independent patented analysis methods to ensure that the test results are better than national standards.
★The fertilizer print result is a percentage, and the test error is less than 0.5%.
Multiple functions and complete test items:
Fertilizer nutrients: ● Nitrogen, phosphorus, and potassium in single-element fertilizers; ● Ammonium nitrogen, nitrate nitrogen, phosphorus, potassium, and biuret in compound (mixed) fertilizers and urea; ● Quick-acting nitrogen, quick-acting phosphorus, quick-acting potassium, total nitrogen, total phosphorus, total potassium, organic matter, various humic acids, etc. in organic fertilizers (foliar fertilizers). It can be expanded to detect trace elements such as calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, molybdenum, and various heavy metals (lead, chromium, cadmium, mercury, arsenic, nickel, aluminum, fluorine, titanium, and selenium).
Technical indicators:
Power supply: AC 220±22V DC 12V+5V (vehicle power supply or built-in lithium battery can be selected)
2. Power: ≤5W
3. Range and resolution: 0.001-9999
4. Repeatability error: ≤0.02% (0.0002, potassium dichromate solution)
5. Instrument stability: drift within one hour is less than 0.3% (0.003, transmittance measurement). After the instrument is turned on and preheated for 5 minutes, the displayed digital display has no drift within 30 minutes (transmittance measurement), and the digital drift within one hour does not exceed 0.3% (0.003, transmittance measurement); within three hours, the digital drift does not exceed 0.7% (0.007, transmittance measurement), 0.002 (absorbance measurement).
6. Linear error: ≤0.1% (0.001, copper sulfate detection)
7. Sensitivity: red light ≥4.5 × 10-5 blue light ≥3.17 × 10-3 green light ≥2.35 × 10-3 orange light ≥2.13 × 10-3
8. Wavelength range: red light: 680 ± 2nm; blue light: 420 ± 2nm; green light: 510 ± 2nm; orange light: 590 ± 4nm
9. PH value (acidity): (1) Test range: 1 to 14 (2) Accuracy: 0.01 (3) Error: ±0.1
10. Simultaneous, rapid and accurate detection of nutrients such as nitrogen (N), phosphorus (P), potassium (K) in fertilizers
11. Test speed: ≤50 minutes to test one fertilizer sample (N, P, K) (including pre-processing time, no accessories required by the user)
12. ≤2 hours to test 5 fertilizer samples at the same time (including pre-processing time)
13. Data printing: built-in new one-button thermal printer
Test speed:
8 samples can be tested simultaneously;
Test one compound fertilizer sample (N, P, K) ≤50 minutes; 20 minutes more time for each additional fertilizer sample.
Test one organic fertilizer sample (N, P, K, organic matter) ≤1.5 hours; 30 minutes more time for each additional sample.
Test error:
The single error of fertilizer is ≤0.5%, and the total error of nitrogen, phosphorus and potassium is ≤1%.
Instrument features:
Full functions: Comprehensive test items at home and abroad (all kinds of agents can be purchased).
Completely equipped, the instrument integrates medicine, equipment and instrumentation, is easy to carry, and is equivalent to a small laboratory. Users only need to provide distilled water to complete all operations within the required time.
Reliable performance: The working stability is more than 8 times better than the national standard JJG179-90 index, and the repeatability reaches the index level of the grating spectrophotometer.
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.