Fixed ultrasonic flowmeter TDS-100F DN50mm-700mm M2 Transducer Liquid Flow Meter

Model No.︰

TDS-100F

Brand Name︰

AERMANDA

Country of Origin︰

China

16 Items sold in last 3 minutes

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

19 People watching this product now!
Description

Is stationary time difference ultrasonic flowmeter flow body could be water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured.

Widely used in industrial field of various liquid flow metering online, which host is divided into standard wall hanging type, plate type, hanging type explosion-proof, the use of different field in order to meet user needs.

 

Product features

Low fixed ultrasonic flowmeter with large planning integrated circuits CPLD, table process, accuracy is higher.

Price, high reliability, high performance, good applicability, full display in Chinese.

Day, month and year flow accumulation function, can record run 64 days before the operation, the first 64 months, the first five years of accumulated flow operation.

On low, the power management function, can record, electricity and traffic on 64 times before, can be manually or automatically compensate to reduce flow losses.

Low effectively overcome the wall of the ultrasonic signal attenuation and rough surface of the pipe to scattering of ultrasonic signal from surface reduce the energy consumption of ultrasonic signal.

Low overcame a signal to a small amount of sediment, suspended particles and bubbles, the effect of improved flow measurement accuracy, especially suitable for pipe flow measurement.

When using a dedicated open hole tool that sensor in the zone without water supply installation, unique belt roller disassembly, installation method, does not affect the normal production,

at any time to complete the on-line replacement and maintenance.

 

Linearity Better than ±1%.
Accuracy ±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile.
Repeatability ±0.2%.
Velocity ±0.03 ~ ±105 ft/s
(±0.01 ~ ±30 m/s), bi-directional
Measurement Period 0.5s
Display LCD with backlight.  2×20 letters.
Keypad 4×4-key membrane keypad with
tactile feedback
Units English (U.S.) or metric.
Outputs Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .
Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc.
Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc.
Internal Alarm (Buzzer): user programmable.
External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm.
RS-232 serial port.
Input Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.
Two of the five input channels are wired to terminal blocks. The remaining three channels are optional.
Enclosure Die-cast aluminum enclosure.
Protection Class:  IP65 (NEMA 4X).
Size: 9.88×7.56×3.15 (251x192x80mm3) for standard version
Clamp-on S2-type: for pipe size  (DN15~DN100mm)
M2-type: for pipe size (DN50~DN700mm)
L2-type: for pipe size (DN300~DN6,000mm)
Liquid Types Virtually all commonly used clean liquids.
Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm.
Liquids should contain no or very minor air bubbles.
Examples are chilled/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.
Liquid Temp (0C – 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult us for assistance.
(0C – 160C) for wetted transducer.
Pipe Size 1 ~ 240 (DN15mm ~ DN6,000mm).
Pipe Material All metals, most plastics, fiber glass, etc.  Allow pipe liner.
Cable Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m).  Contact us for longer cable requirement.
Power AC: 240V DC: 8VDC~36VDC
Power consumption: < 2W
Weight Standard main unit: 6.6lb (3kg)

 

Transducer Standard S2 type Standard M2 type Standard L2 type    
Suitable pipe diameter DN15-DN100mm DN50-DN700mm DN300-DN6000mm    
Fluid temperature 0°c-160°c 0°c-160°c 0°c-160°c    
Outer size 45×30×30mm 60×45×45 80×70×55    
Quality 75g 250g 528g    

 

Standard Packing:

TDS-100F Ultrasonic Flowmeter

Clamp Fixture

Standard M2 Transducer

2 x 5m Signal Cable

 

If you need other transducer or extend the signal cable length, please contact us.

Price Terms︰ FOB Shenzhen
Payment Terms︰ TT/Western Union/Paypal
Packing︰ Export carton
Lead Time︰ 4 days

Product Image

Wall-mount hostWall-mount host

TDS-100FTDS-100F

M2 TransducerM2 Transducer

Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “Fixed ultrasonic flowmeter TDS-100F DN50mm-700mm M2 Transducer Liquid Flow Meter”

Your email address will not be published. Required fields are marked *