Horizontal steam sterilizer
1,520.00৳
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
-
valid capacity :150L 200L 280L 400L 500L
-
working pressure:0.22Mpa
-
Maximum safety pressure:0.165Mpa
-
working temperature :134℃
-
heat average :≤±2℃
-
Time for sterilization:0-60min
-
Time for drying:0-60min
-
temperature range :40℃-134℃
wholesale custom home large portable rapid steam sterilizer
Use
The horizontal autoclave, which adopte the way of gravity exchange to release the cold air from the chamber
more completely toensure the reliable sterilization.The control system automatically adjust the steam inlet and
outlet according to chambertemperature during sterilizing. This unit is an ideal equipment for clinics,scientific
research institutes and other organizations tosterilize surgical instruments, fabric glassed, and the culture media etc.
High-pressure steam sterilizer is a device that uses saturated pressure steam to sterilize items quickly and reliably.
It is suitable for medical and health, scientific research, agriculture and other units. Autoclave sterilizers are divided
into portable autoclave sterilizers, vertical autoclave sterilizers, and horizontal autoclave sterilizers according to style
and size. It can sterilize medical equipment, dressings, glassware, solution culture medium, etc.
Characteristics
• Automatially controlled the sterilizing process, easy to operate.
• With drying function, suitable for the medical dressing drying.
• With overtemperature, overpressure autoprotect.
• The door can not be open until the pressure in the chamber is reduced to 0.027MPa. And the unit can not be started on if the Idoor doesn’t close well.
• The safety valve will be open automatically when the inner pressure over 0.24MPa and the steam would be exhausted the water tank.
• Automatically cut off the power if the waterlack happened, and alarm at the meanwhile.
• The chamber of the sterilizer is made of stainless steel.
Technical Data
MODEL | WS-150YDA | WS-200YDA | WS-280YDA | WS-400YDA | WS-500YDA | |
---|---|---|---|---|---|---|
Technical Data | ||||||
Stenilizing chamber volume | 150Lφ440×1000 | 200Lφ515×1000 | 280Lφ600×1000 | 400Lφ700×1100 | 500Lφ700×1300mm | |
Working pressure | 0.22Mpa | |||||
Working temperature | 134℃ | |||||
Temperature adjust range | 40℃-134℃ | |||||
Time for sterilization | 0-60min | |||||
Time for drying | 0-60min | |||||
Heat average | ≤±2℃ | |||||
Power | 9kw/380V 50Hz | 9kw/380V 50Hz | 12kw/380V 50Hz | 18kw/380V 50Hz | 18kw/380V 50Hz | |
Dimension(mm) | 1400×600×1300 | 1400×670×1650 | 1400×770×1780 | 1430×880×1830 | 1800×900×1820 | |
Exerior package dimension(mm) | 1550×750×1850 | 1560×820×1850 | 1680×920×2100 | 1600×1050×2100 | 1850×1050×2100 | |
G.W/N.W | 320/240kg | 350/260kg | 465/365Kg | 530/420Kg | 580/470Kg |
Autoclave Sterilizer Time Control:
1. In general, the lower the sterilization temperature, the longer the sterilization time required by the autoclave; the higher the sterilization temperature,
the shorter the sterilization time required by the autoclave. However, the time of pressure steam sterilization should be counted from the time when the
autoclave chamber reaches the required sterilization temperature until the sterilization is completed.
2. Total autoclave time includes:
Thermal penetration time, that is, the time required from reaching the sterilization temperature in the sterilization cabinet to the time when the center
of the sterilized item also reaches the sterilization temperature. The length of time depends on the nature of the items to be sterilized, the size of the package,
the location and the degree of air evacuation in the autoclave and the type of sterilizer.
Sterilization maintenance time, that is, the time required to kill microorganisms, is generally expressed by the time required to kill Thermobacter stearothermophilus
spores. 30 minutes at 115°C, 12 minutes at 121°C, and 2 minutes at 132°C.
3. The safety time is generally half of the maintenance time, and its length depends on the disinfection items. Sterilization of thermally conductive metal equipment
does not require a safe time.
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.