i Series UV-VIS Spectrophotometer i2/i3/i5/i6/i7/i8/i9

1,520.00৳ 

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

Description

i2 Visible Spectrophotometer

1 .Standard scanning software can directly complete functions of Quantitative;Kinetics;Wavelength Scan; Multi Wavelength; DNA/Protein and Data processing.

2. Can establish calibration curves and implement associated tests. The instrument internal can be stored with 200 groups of data and 200 standard curves.

3. Suspended posture optical system design, strengthen and thicken the bottom plate to eliminate the vibration or transformation’s impact on the optical system.

4. Automatic wavelength calibration and automatic deviation repair.

5. Tungsten and Deuterium lamp can be changed easily, without adjustment.

6. Standard with PC software.

 

i3 UV-VIS Spectrophotometer

1 .Standard quantitative software can directly complete photometric analysis, quantitative test and processing of analytical data.

2. Can establish calibration curves and implement associated tests. The instrument internal can be stored with 200 groups of data and 200 standard curves.

3. With calibration curve method, we can establish multiple-point standard curve directly, on basis of which we can measure the concentration of the unknown sample.

4. With coefficient method, we can implement sample measurement directly after inputting coefficient of the curvilinear equation.

5. Automatic wavelength calibration and automatic deviation repair.

6. Deuterium and tungsten lamp can be changed easily, without adjustment.

7.Standard with PC software

 

i9 Double-Beam UV-VIS Spectrophotometer

1. Double- beam optical system.

2. The Main unit and PC software can independently implement functions of Quantitative;Kinetics;Wavelength Scan; Multi Wavelength; DNA/Protein and Data Printing,PC software can complete the function of data processing.

3. Suspended posture optical system design, strengthen and thicken the bottom plate to eliminate the vibration or transformation impact on the optical system.

4.24-bit high speed and high precision A/D conversion, and improve the sensitivity of the instrument.

5.0.5/1.0/2.0/4.0/5.0 bandwidth can be adjusted automatically

6. The core components are imported with original packaging.

7. Optical system based on optical system, based on top structure design, top technological requirements and top raw materials.

8. Standard with PC software

 

Technical data

i2 i3 i5 i6 i7 i8 i9
Wavelength Range 320-1100nm 190-1100nm 190-1100nm 190-1100nm 190-1100nm 190-1100nm 190-1100nm
Bandwidth 2nm 2nm 1.8nm 1.8nm 0.5/1/2/4nm 1.8nm 0.5/1/2/4/5nm
Wavelength Accuracy ±0.5nm ±1nm ±0.5nm ±0.1nm (D2 656.1 nm); ±0.3nm (Full range)
Wavelength Reproducibility ≤0.2nm ≤0.3nm ≤0.2nm ≤1nm ≤0.1nm ≤0.1nm ≤0.1nm
Photometric Accuracy ±0.3%T ±0.5%T ±0.3%T ±0.2%T ±0.2%T ±0.2%T ±0.2%T
Photometric Repeatability 0.15% T <0.2%T <0.15%T <0.15%T <0.15%T <0.15%T <0.15%T
Straylight <0.05%T <0.05%T <0.05%T <0.03%T <0.03%T <0.03%T <0.03%T
Stability ±0.0001A/h(500nm) ±0.001 A/h(at 500nm) ±0.0004A/h(at 500nm)
Baseline Flatness ±0.001 A/h ±0.0005A ±0.001A ±0.0015A ±0.0015A ±0.001A ±0.001A
Noise ±0.0005A/h ±0.001A ±0.0005A ±0.0005A ±0.0005A ±0.0005A ±0.0005A
Photometric Range *’0-200%T, -0.3-3A, 0-9999C 0-200%T, -4.0-4.0A, 0-9999C
Wavelength setting mode Automatic Automatic Automatic Automatic Automatic Automatic Automatic
Scanning speed High,Middle,Low,Optional
Output USB Port
Printer port Parallel Port
Display LCD(320*240)
Light Source Tungsten Lamp Deuterium&Tungsten Halogen Lamp
Detector Silicon Photodiode
Power 220V AC ±10%/50Hz or 110V AC/ 60Hz
Dimension 460x380x180mm 420x300x160mm 460x380x180mm 470x370x180mm 470x370x180mm 625x430x210mm 625x430x210mm
Weight 15Kg 13Kg 20Kg 20kg 20kg 28Kg 28Kg

 

 

i5 UV-VIS Spectrophotometer

1. The main unit and PC software can independently implement functions of Quantitative;Kinetics;Wavelength

Scan; Multi Wavelength; DNA/Protein and Data Printing,PC software can complete the function of data processing.

2. Strong function of data processing makes user editing can be easier and more convenient.

3. Suspended posture optical system design, strengthen and thicken the bottom plate to eliminate the vibration or transformation’s impact on the optical system.

4. Adopt synchronous sine institutions, high accuracy of the wavelength, repeatability.

5. Standard with PC software

 

i6 UV-VIS Spectrophotometer

1. The Main unit and PC software can independently implement functions of Quantitative; Kinetics; Wavelength Scan; Multi Wavelength; DNA/Protein and Data Printing; PC software can complete the function of data processing.

2. Suspended posture optical system design, strengthen and thicken the bottom plate to eliminate the vibration or transformation’s impact on the optical system.

3. 24-bit high speed and high precision A/D conversion, and improve the sensitivity of the instrument.

4. The core components are imported from Germany and Japan.

 

i7 UV-VIS Spectrophotometer

1. The Main unit and PC software can independently implement functions of Quantitative; Kinetics; Wavelength Scan; Multi Wavelength; DNA/Protein and Data Printing; PC software can complete the function of data processing.

2. Suspended posture optical system design, strengthen and thicken the bottom plate to eliminate the vibration or transformation’s impact on the optical system.

3. 24-bit high speed and high precision A/D conversion, and improve the sensitivity of the instrument.

4. The core components are imported from Germany and Japan.

5. 0.5/1/2/4nm bandwidth can be adjusted automatically.

 

i8 Double-Beam UV-VIS Spectrophotometer

1. Double beam optical system.

2. The Main unit and PC software can independently implement functions of Quantitative;Kinetics;Wavelength Scan; Multi Wavelength; DNA/Protein and Data Printing,PC software can complete the function of data processing.

3.Suspended posture optical system design, strengthen and thicken the bottom plate to eliminate the vibration or transformation’s impact on the optical system.

4.24-bit high speed and high precision A/D conversion, and improve the sensitivity of the instrument.

5.The core components are imported from Germany and Japan.

6.Optical system based on optical system, based on top structure design, top technological requirements and top raw materials.

7.Standard with PC software

Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “i Series UV-VIS Spectrophotometer i2/i3/i5/i6/i7/i8/i9”

Your email address will not be published. Required fields are marked *