MS104K Four-In-One Gas Detector
It can be used in rapid detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will emit sound & light vibration as alarm. We provide gas detector OEM/ODM serves.
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
Details
MS104K Portable Toxic and Harmful Gas Detector
It can be used in rapid detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will emit sound & light vibration as alarm.It adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. It is possible to simultaneously detect 1 ~ 4 types of gases, and the units can be switched freely.
Tag: Diffusion gas monitor, Single gas detector , Gas leak detector, Gas alarm detector, Hydrogen gas analyzer, Sulfur Dioxide detector, Ethylene oxide leak monitor, OEM/ODM gas detector
Parameter
Gases to be detected
|
Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements.
|
||||
Application scenarios
|
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
|
||||
Detection range
|
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
|
||||
Resolution
|
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol |
||||
Detection principle
|
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
|
||||
Sensor service life
|
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. |
||||
Allowable error
|
≤±3% F.S (higher precision levels can be customized)
|
||||
Linearity
|
≤±2%
|
Repeatability
|
≤±2%
|
Uncertainty
|
≤±2%
|
Response time
|
T90≤30 seconds
|
Recovery time
|
≤30 seconds
|
||
Working environment
|
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH
|
||||
Sample gas temperature
|
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect
the smoke gas at the temperature of 400 ℃ or higher. |
||||
Temperature and humidity measurement
|
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
|
||||
Power supply
|
3.7VDC, 3000mA high capacity rechargeable polymer battery
|
||||
Display mode
|
2.31-inch high-definition color screen
|
||||
Detection mode
|
Diffusion type measurement. The calibrated flow rate is 500 ml/minute.
|
||||
Alarm mode
|
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
|
||||
Communication interface
|
USB (charging and communication), optional: RS485 communication interface
|
||||
Data storage
|
Standard configuration is the data storage capacity for 100, 000 entries
|
||||
Protection level
|
IP65
|
||||
Explosion-proof type
|
Intrinsically safe type
|
||||
Explosion-proof mark
|
Exia II CT4 Ga
|
||||
Exterior dimensions
|
130×68×34mm (L×W×H)
|
||||
Weight
|
200g
|
||||
Standard accessories
|
Manual, qualification certificate, warranty card, USB charger (including the data cable), belt clip, colorful packaging box (optional high-grade aluminum instrument case)
|
||||
Optional items
|
Temperature and humidity measurement function, external gas sampling pump, 1.2 m retractable sampling handle (1-10 meter hose, and
the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable) |
Application
Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis, air treatment and all other occasions that need to detect and analyze gas concentration.
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.