MS600 Portable 6 in 1 Monitor
The MS600 measures up to 6 gases, including toxic, flammable gases and vapors, and oxygen all at once with internal pump and rechargeable battery. Innovative signaling design and handy wizard functions ensure complete safety throughout the process. We provide gas detector OEM/ODM serves.
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
Details
MS600 Portable 6 in 1 Monitor
MS600 Portable Multi Gas Detector can be used in: mobile rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound with flash light.
It adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on.
It is possible to simultaneously detect 1 ~ 6 types of gases, and the units can be switched freely. The types for detection are more than 500 types.
Gases to be detected | Range | Allowable | Minimum reading | Response time T90 |
Combustible gas ( EX ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤10 seconds |
Methane ( CH4 ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤10 seconds |
Oxygen gas ( O2 ) | 0-30%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
Carbon monoxide ( CO ) | 0-100ppm | <±2%(F.S) | 0.1ppm | ≤25 seconds |
Carbon dioxide ( CO2 ) | 0-500ppm | <±2%(F.S) | 1ppm | ≤20 seconds |
Ozone ( O3 ) | 0-1ppm | <±2%(F.S) | 0.001ppm | ≤20 seconds |
Hydrogen sulfide ( H2S ) | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
Sulfur dioxide ( SO2 ) | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
Nitric oxide ( NO ) | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
TotalVolatileOrganic | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
Compound gases | ||||
( TVOC ) | ||||
Volatile gases ( PID ) | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
Tag: Pump gas monitor, Multi gas detector , Gas leak detector, 6 in1 gas alarm detector, Nitric oxide gas analyzer, Electrochemical gas detector, Methane leak monitor, OEM/ODM gas detector.
Parameter
Gases to be detected
|
monitor up to 6 gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.Optional configuration: temperature and humidity measurements.
|
||||
Application scenarios
|
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
|
||||
Detection range
|
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
|
||||
Resolution
|
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%LEL 0.001% Vol |
||||
Detection principle
|
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand.
|
||||
Sensor service life
|
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected;
Infrared principle: 5 ~ 10 years;
Catalytic combustion: 3 years; Thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
|
||||
Allowable error
|
≤±1% F.S (other precision levels can be customized)
|
||||
Linearity
|
≤±1%
|
Repeatability
|
≤±1%
|
Uncertainty
|
≤±1%
|
Response time
|
T90≤20 seconds
|
Recovery time
|
≤30 seconds
|
||
Working environment
|
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
|
||||
Sample gas temperature
|
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
|
||||
Temperature and humidity measurement
|
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
|
||||
Power supply
|
3.6VDC, 6000mA high capacity rechargeable polymer battery
|
||||
Display mode
|
2.5-inch high-definition color screen
|
||||
Detection mode
|
Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass |
||||
Alarm mode
|
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
|
||||
Communication interface
|
USB (charging and communication), optional: RS232, infrared communication, automatic recognition
|
Application
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.