Maximize your softener cycle time and minimize your regeneration cost.
Immediately signal hardness breakthrough to activate regeneration. Makes your water softening system more efficient and less costly. Reliable, simple and accurate- with automated calibration. Continuous monitoring in “real time”.
Applications:
- Membrane Protection
Benefits
Continuous Hardness Detection
The Hach SP 510 Hardness Monitor continuously monitors water systems to provide an alarm when total hardness exceeds a pre-set limit (eight alarms are available). By performing an analysis every two minutes, the SP 510 monitor can establish an automatic or semi-automatic system for water softener regeneration in a variety of commercial or industrial applications.
Simple to Read and Use
The SP 510 monitor detects hardness breakthrough when the capacity of a water softener is exhausted, immediately signaling the need for regeneration. Alarm points are 0.3, 1, 2, 5, 10, 20, 50, and 100 ppm (expressed as mg/L of CaCO3) and are selected by using the appropriate model. LED indicators show a simple HARD or SOFT sample status. Use the monitor’s built-in alarm relay to actuate an external annunciator.
Rugged, lightweight, and self-contained
The case of the SP 510 monitor is made of ABS plastic which is lightweight, corrosion-resistant, and shatterproof. This sealed case is IP62-rated and has a hinged door that for easy access to internal components. All electronic circuits are isolated from the hydraulics compartment. A large window allows inspection of both LED indicators and reagent supplies at a glance. Wall-mounting is easy with built-in brackets. The instrument is rated for 115/220 Vac, 50/60 Hz operation, with a switch for voltage selection.
Making Water Softening Systems Cost-efficient
The traditional method of determining softener regeneration cycles is based on calculation of the water volume that can pass through a softener before its capacity is exhausted. Many variables (temperature, flow rate, and condition of the exchange resin) can affect the accuracy of these calculations. A substantial safety margin is also generally included, which can result in waste of time and brine used for regeneration. The Hach SP 510 monitor can eliminate this guesswork. The softener is regenerated only when needed, based on accurate chemical analysis rather than estimated volume.
Low Maintenance Requirements
The SP 510 monitor is designed for continuous, unattended use. It is virtually maintenance-free, requiring only about 15 minutes every two months to replenish and standardize the reagents. Tubing in the pump system should be replaced at six-month intervals. Spare pump tubing is supplied with the monitor.
Method of Analysis
The Hach SP 510 Hardness monitor uses an aqueous buffered colorimetric indicator to detect total hardness. Color is developed by addition and mixing of a sample, indicator reagent, and buffer in precise proportions.
A blue color indicates soft water and creates low light transmittance; a red color indicates hard water and creates high light transmittance. The colorimeter assembly measures the transmitted light and differentiates between the colors.When the measured light is 50% or more of the pre-set level, alarm circuits are activated.
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.