TH-1000 Continuous Emission Monitoring System

The on-line monitoring and pretreatment system is applied to 24-hour continuous on-line monitoring of on-site gas concentration. It is equipped with 7-inch high-definition color screen to display on-site concentration, over standard on-site audible and visual alarm (optional), remote signal GPRS, DTU, Lora and other transmission. The gas sensor of international famous brand is adopted. The main detection principles include: gas sensor based on the principles of electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photo ion, etc..

11 Items sold in last 3 minutes

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

18 People watching this product now!
Description

Details

Optional 1-6 kinds of compound gas detectors

Concentration display unit can be switched freely

A variety of communication methods are available

Real-time monitoring via wired or wireless remote transmission, network transmission; 3-wire 4-20mA standard signal and standard bus RS485 (modbus-RTU) output at the same time; optional frequency output 200-1000Hz, Hart protocol signal, 1-5V output, 2-wire 4-20mA, SMS alarm, wireless transmission (2-5km or unlimited distance); compatible with secondary instruments, data acquisition modules, PLC, DCS system, can drive related equipment. 

Infrared remote control
Standard infrared remote control, through the infrared remote control function keys can be one-touch operation, can realize in dangerous occasions without opening the cover operation, such as: modify the alarm point, concentration calibration, zero calibration, silence, restore factory and other functions.

Rich human-machine interface
1.7″ HD color screen, display real-time concentration, alarm status.

High temperature gas detection (optional)
Optional high temperature and high humidity pre-treatment system can detect high temperature flue gas.

Data recovery function, you can select partial or full recovery in case of misoperation

The maximum value and minimum value can be set to be displayed or not

Multiple alarm modes, multi-directional indication of alarm status during alarm 
Include: 2 groups of relay switch output, sound and light alarm (optional), display visual alarm.
Alarm types include: concentration alarm, fault alarm.  
Multiple alarm mode settings: low alarm, high alarm, interval alarm, weighted average alarm

Misoperation identification function: concentration calibration misoperation is automatically identified and prevented to avoid bad human factors

Zero point automatic tracking, long-term use is not affected by zero point drift

Multi-stage calibration of target point to ensure linearity and accuracy of measurement

Chinese or English interface can be selected

Wide working temperature: -40~+70℃, support temperature compensation

Logging
Record calibration log, maintenance log, fault record, troubleshooting countermeasures, sensor life expiration reminder, next concentration calibration time reminder function.

Intrinsically safe circuit design, explosion-proof, with secondary lightning protection and anti-static capability. Meet national standards and resist high-intensity pulse surge current impact. With anti-reverse connection function. Meets EMI, EMC standards.

Parameter

 

Detecting gas Toxic gases, oxygen, carbon dioxide, flammable and explosive gases, TVOC, etc.
Applications Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, storage, flue gas analysis, air treatment and all other occasions that require fixed installation and online detection of gas concentration.
Testing range 01101001000500050000100000ppm200ml/L100%LEL20%50%99.999%100%Vol OptionalOther ranges can be customized
Resolution 0.01ppm0.001ppm010 ppm);0.01ppm0100 ppm,0.1ppm01000 ppm),1ppm0~ more than 1000 ppm),0.01ml/L0200%ml/L)、0.1%LEL0.01%0.001%Vol
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on gas type, range, site environment and user requirements.
Sensor life Electrochemical principle 2 to 3 years, oxygen 2 years or 6 years optional, infrared principle 5 to 10 years, catalytic combustion 3 years, thermal conductivity 5 years.
Detection accuracy ≤±3%F.S  (Higher precision can be customized
Linearity ≤±2%
Repeatability ≤±2%
Uncertainty ≤±2%
Recovery time 3second
Response time T902second
Signal Output Bus system RS485 (RTU), three (four) wire system 420mA, optional: 020mA, 15V, 05V, 010V, wireless transmission, network transmission, SMS alarm.
Working Environment Temperature40℃+70℃Humidity1095%RH (GeneralNon-condensing occasions in the use of condensing occasions must be custom-made or specify the use of environment when ordering
Display On-site 1.7″ HD color screen display, optional on-site no display, or optional MIC2000 controller remote display, control, alarm
Working Voltage 12 to 36VDC, 24V, 1A or more than 1A DC regulated switching power supply as standard for a single device
Power 24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors
Operation mode Fixed installation, online detection, diffusion measurement; optional pipeline, circulation, pump suction measurement
Installation method Pipeline type, wall-mounted type. The working pressure of pipeline type is ±30% of atmospheric pressure, beyond the range need to reduce the pressure treatment.
Alarm method Default 1 way, optional 2 way passive contact (dry node) output, three level alarm, alarm point can be set. Live sound and light alarm (optional)
Connection Cable 4 ~ 20mA selected three-core shielded cable, RS485 selected four-core, the distance of more than 1000 meters when the single wire diameter ≥ 1.5mm; shielding layer to earth.
Protection level IP65 (Probes)
Explosion-proof type Explosion-proof type (Probes)
Explosion-proof signs ExdⅡCT6(Probes)
Execution Standards GB15322.1-2003

GB 3836.1—2010 

GB 3836.2—2010 

External size 400×180×600mm(L×H×W)
Weight 1.8Kg(Probes)
Standard Accessories Instruction manual, certificate of conformity, warranty card, outer box packaging box
Options One-piece sound and light alarm, split sound and light alarm, 24V DC regulated power supply, accessories for computer monitoring: free host software, RS485/RS232 converter, USB/RS232 conversion cable for laptops without RS232 interface, and TCP/IP converter for network transmission.
Wireless transmission Optional function, you can wirelessly transmit data to cell phones, remote monitoring centers, monitoring computers and other monitoring equipment, using the computer on the computer, data analysis, storage, printing and other functions
Pretreatment system Optional: Normal temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system
Mounting accessories Optional: wall mounting bracket, mounting buckle fixed on the pipeline (four or six branch pipes), stainless steel threaded welding seat or flange for pipeline installation (pipe or flange size shall be indicated, such as DN50, DN15…) Rain cover, 24VDC or 220ac sampling pump (sampling distance 10m), vacuum pump (sampling distance greater than 40m), 24V switching power supply, pressure reducing valve and flowmeter.

Application

It is widely used in petroleum, chemical industry, metallurgy, refining, gas transmission and distribution, biochemical medicine and other industries.

Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “TH-1000 Continuous Emission Monitoring System”

Your email address will not be published. Required fields are marked *