Zetron Atmospheric Pollutants Online Gas Monitoring System
1,000.00৳
Gas monitoring system is made of stainless steel, aluminum alloy, high-quality cold plate, aluminum-magnesium zinc plate mixed material, is designed for the open-air outdoor environment and all-weather equipment protection box, with rain, dust, ventilation fan heat, anti-UV (anti-aging), rust, acid and alkali corrosion, electromagnetic interference (lightning) characteristics, the box adopts a high degree of freedom modular quick-disassembly structure, easy to Quick installation of equipment and later maintenance.
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
Details
TH2000 Air Pollution Exhaust Gas Monitoring Equipment
TH2000 is made of stainless steel, aluminum alloy, high-quality cold plate, aluminum-magnesium zinc plate mixed material, is designed for the open-air outdoor environment and all-weather equipment protection box, volume 60 * 60 * 1000px, with rain, dust, ventilation fan heat, anti-UV (anti-aging), rust, acid and alkali corrosion, electromagnetic interference (lightning) characteristics, the box adopts a high degree of freedom modular quick-disassembly structure, easy to Quick installation of equipment and later maintenance.
There are 1.2m and 1.5m optional, equipped with two clamps and screws, easy to install. The base size is 30*750px, with four 10mm expansion screws recommended for installation and fixing.
Tag: Exhaust Gas Detector, Gas Monitoring Alarm Equipment, Factory Boundary Gas Monitor,Air Pollution,Toxic Gases Detector, Air Pollution Dust Detector, OEM/ODM gas alarm device
Parameter
Working mode | fixed installation, online detection, diffusion measurement, pipeline type (M45X1.5 male thread), circulation type, pump suction type optional. |
Installation method | pipeline type, wall-mounted type. The working pressure of pipeline type is ±30% of the atmospheric pressure, beyond the range need to reduce the pressure treatment. |
Response time | T90 ≤ 20 seconds (TVOC using light ion principle is less than 15 seconds) |
Recovery time | ≤ 30 seconds |
Working environment | -40℃~+70℃ |
Relative humidity | ≤10-95%RH (conventional) non-condensing occasions |
Operating voltage | 12~30V (DC DC, the standard power supply of single device is 24V, 1A or DC switching power supply greater than 1A) |
Size | 60 * 60 * 1000 |
Explosion-proof form | ExdⅡCT6 |
Protection level | IP66 |
Application
All the cases which requires the fixed installation, and online detection of gas concentrations such as Chemical Industry, Power Generation Plants, Natural Gas Pipeline & Processing, Pulp & Paper Industry, Waste Water Treatment Plants, Commercial & Industrial HVAC, Acetylene Gas Bottlers & Users , Ice Skating & Hockey Arenas,Breweries and so on.
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.