HiPette 0.1ul-10000ul laboratory Pipette

1,520.00৳ 

OEM:Available
Sample:Refuse
Port:Nan shaPort,HUANGPU,YANTIAN,SHEKOU
Payment:Other,PayPal,VISA,Western Union,T/T,MasterCard,L/C,D/P,D/A
Place of Origin:China
Shipping:Support Express · Sea freight · Land freight · Air freight
Supply Ability:1000 piece per day

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

Description
Quick Details
  • Model Number:
    HiPette Pipettor
  • Brand Name:
    IKEME
  • Color:
    Blue
  • Sterile:
    Whole Sterile
  • Design:
    Light Weight Ergonomic
  • Volume:
    0.1ul-10000ul
  • Classification:
    PIPETTE
  • Pipette use:
    Laboratory Liquid
  • Single package size:
    30X10X6 cm
  • Single gross weight:
    0.5 KG
 Key Features
  1. Introducing the new generation of fully autoclavable manual pipettes – the IKEME pipette.
  2. Ergonomic Design: The IKEME pipette is designed with excellent ergonomics that reduce fatigue and provide a smoother and easier pipetting experience.
  3. Smooth and Effortless Operation: With a one-stop point of 4N and two-stop points of 10N, the IKEME  pipette offers a comfortable single-handed pipetting experience with smooth and effortless operation.
  4. Multiple Volume Range: The IKEME  pipette offers nine different single-channel adjustable volume models, ranging from 0.1 µl to 10 ml, making it ideal for various laboratory applications.
  5. Precise Volume Setting: The IKEME  pipette features a new piston and metal screw structure, ensuring precise suction and dispensing of liquids. Its counter increment is one thousandth of the volume range, making it easy to set and read.
  6. One-Click Volume Lock: The IKEME  pipette has a one-click volume lock feature that helps prevent pipetting errors caused by accidental volume changes, allowing for more accurate transfer of small volumes of liquids.
  7. Smooth Volume Adjustment: The IKEME  pipette offers a smooth and easy volume adjustment experience, ensuring high precision and accuracy.
  8. High-Quality Materials: The IKEME  pipette is made of a new type of material that does not require disassembly for autoclaving or UV disinfection, and is resistant to harsh chemicals.
  9. Individual Filter System: The IKEME  pipette is equipped with an individual filter system that reduces volatile reagents from entering the pipette and causing over-aspiration or corrosion of the piston.
  10. Easy Maintenance: The IKEME  pipette is easy to disassemble and comes with tools that can be used to calibrate and maintain the pipette in the laboratory.
  11. Certifications: The IKEME  pipette has ISO9001:2015 and ISO 13485:2016 certifications, as well as CE marking, ensuring its quality and reliability.
  12. Online Calibration: The IKEME  pipette can be calibrated online via the official website, ensuring its accuracy and reliability.
  13. Overall, the IKEME  pipette is a reliable, easy-to-use, and precise manual pipette that is ideal for various laboratory applications.
  14. With its ergonomic design, precise volume setting, and high-quality materials, the IKEME  pipette is the ideal choice for any laboratory looking for a reliable and efficient pipette.
Single-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume(μl) Accuracy error  Precision error
% μl % μl
0.1-2.5μl 0.002μl 2.5 1.40% 0.04 0.70% 0.02
1.25 2.50% 0.03 1.50% 0.02
0.25 12.00% 0.03 6.00% 0.02
0.5-10μl 0.1μl 10 1.00% 0.10 0.40% 0.04
5 1.50% 0.08 0.80% 0.04
1 2.50% 0.03 1.80% 0.02
2-20μl 0.02μl 20 1.00% 0.20 0.30% 0.06
10 1.20% 0.12 0.60% 0.06
2 5.00% 0.10 1.50% 0.03
10-100μl 0.1μl 100 0.80% 0.80 0.20% 0.20
50 1.00% 0.50 0.30% 0.15
10 3.00% 0.30 1.00% 0.10
20-200μl 0.2μl 200 0.60% 1.20 0.20% 0.40
100 1.00% 1.00 0.30% 0.30
20 2.50% 0.50 0.70% 0.14
30-300μl 0.2μl 1000 0.60% 1.80 0.20% 0.60
500 1.00% 1.50 0.30% 0.45
100 2.50% 0.75 0.70% 0.21
100-1000μl 1μl 1000 0.60% 6.00 0.20% 2.00
500 1.00% 5.00 0.20% 1.00
100 3.00% 3.00 0.60% 0.60
1000-5000μl 5μl 5000 0.60% 30.00 0.20% 10.00
2500 0.60% 15.00 0.30% 7.50
1000 1.20% 12.00 0.30% 3.00
2000-10000μl 10μl 10000 0.60% 60.00 0.20% 20.00
5000 0.80% 40.00 0.20% 10.00
2000 1.50% 30.00 0.30% 6.00
There is no doubt that pipettes are one of the most important tools in biological research. They come in a variety of designs and are used in countless fields of research.
While many liquid handling guides emphasize the importance of pipette maintenance, pipette technique is just as important.
1. Choose the right pipette and tip: The match between the pipette and the pipette tip is the key to pipetting accuracy. If the tip and pipette do not match, or use poor quality tips,
the seal between the tip and the pipette may be compromised. A good pipette tip ensures a proper seal to minimize sample loss due to leaks.
2. Properly calibrate the pipette according to the liquid density: If the density of the liquid differs greatly from that of the water, recalibrate the pipette. If you are pipetting viscous liquids,
be sure to pipette at a slower speed and work in reverse pipette mode. When pipetting volatile liquids, you need to pipette quickly and use the reverse pipette mode.
3. Pre-wet the tip: To reduce the loss of liquid hanging on the wall, pre-wet the tip at least 3 times. This method of infiltration helps to establish temperature balance and bring humidity
into the dry space within the tip. Skipping this step may affect the accuracy of the dispensed volume due to evaporation or liquid retention.
4. Proper aspiration: Immerse the tip below the surface of the liquid. When sucking liquid, the tip should not be immersed too deeply in the liquid, and the residence time in the liquid
should be about 1S, because immersion too shallow or too deep may lead to inaccurate liquid suction.
5. Pause after each puff: A slow, even, sudden release helps reduce errors. Especially important when dealing with viscous liquids. As much as possible, try to pause for one to two seconds
after each aspiration to allow the liquid level to stabilize in the tip.
6. In the use of the pipette, it is also necessary to pay attention to the inclination angle of the pipette: at the same time, pay attention to the inclination angle of the pipette during operation,
try to ensure vertical suction, and keep the inclination angle range not greater than 20°. When aspirating liquid, try not to touch the wall of the container with the tip, especially when handling
microscopic samples.
7. Adjust to appropriate gear: Use consistent and stable speed and pressure when handling pipettes and samples. In the design of Rainin pipettes, in order to ensure the accuracy of pipetting,
two gears, the first gear and the second gear, are set. You can choose the appropriate gear for pipetting operations according to your experiment and usage habits.
8. Pay attention to temperature: If your experiment allows, make sure that pipettes, tips, and liquids are all at room temperature. Changes in temperature and air pressure can also cause the air
inside the pipette tip to contract or expand, which can affect the accuracy of dispensing liquids. Also, try to avoid overhandling pipettes and tips, as your body temperature may also affect the
amount of liquid dispensed. After the pipetting operation is completed, it can be placed on the pipette holder, not on the laboratory bench.
9. Do a good job in daily maintenance and maintenance: Instrument calibration and daily maintenance are also effective means to prolong the life of the pipette, so it is recommended to clean
and maintain the pipette on a weekly or monthly basis, and calibrate regularly to improve its accuracy.
10. Develop good pipette operation habits: The development of pipetting operation habits is often ignored. Such habits include not only the correct and skilled use of pipette guns, but also the
posture of pipetting experiments. If the pipetting posture Incorrect operation, repeated operations for a long time may cause your muscles to be in a tense state or even muscle strain.
To solve this problem, you can choose an ergonomic pipette and develop good pipetting habits.
Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “HiPette 0.1ul-10000ul laboratory Pipette”

Your email address will not be published. Required fields are marked *