Air Quality Monitoring Micro Station – Atmospheric Network
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
-
- Mall catalog number: TS WES-C
- Brand: Tsingsense
The product can be customized according to customer needs, please contact customer service or sales to provide the sensor configuration you need, please consult the price
Customer service or sales contact number: 400-801-6230
Environmental protection monitoring comes first, and automation and informatization are the prerequisites and guarantees for environmental monitoring. While the local economy is developing rapidly, there are constantly disagreements in various regions
Environmental pollution incidents such as water, gas, and noise of the same degree have seriously affected people’s quality of life and hindered the sustainable development of the local economy. With the various developed by the state
With the promulgation and implementation of environmental protection policies and regulations, local governments at all levels have increased their investment in environmental monitoring while paying more and more attention to environmental governance within their jurisdictions.
Atmospheric environmental quality monitoring stations have been planned and installed in various regions to implement urban air quality forecasting. The WES-C series city-level atmospheric environment monitoring system can be fully realized
The actual needs of the regional environmental protection monitoring department for environmental monitoring to meet the requirements of urban air quality forecasting.
Air Quality Monitoring Micro Station – Atmospheric Grid Automatic Monitoring System Quotation – Product Introduction
TS WES-C Pump-Suction Atmospheric Grid Ambient Air Quality Monitoring System is a kind of online atmospheric environment monitoring equipment launched by our company, which can monitor temperature
Humidity, air pressure, wind speed and direction, rainfall, radiation, ultraviolet rays and other meteorological elements, while monitoring CO, O3, NO2, SO2, H2S, NO, TVOC, NH3,
HCL, PM2.5/10, noise and other environmental factors. The monitored data is transmitted to the data terminal in real time; and record it in a timely manner; Establish a database of monitoring systems, based on historical records
The data and analysis results predict and predict the environmental pollution status and development trend of the jurisdiction, and provide a scientific basis for the effective control of the environmental situation in the jurisdiction. Widely used in cities with
Enterprise atmospheric environment monitoring, atmospheric grid, factory unorganized emission of pollutant gas monitoring, etc.
Air Quality Monitoring Micro Station – Atmospheric Grid Automatic Monitoring System Quote – Product Features
◆ The working system is stable
◆ Simple and convenient installation
◆ Adopt pump-suction sampling method
◆ Imported probe is adopted, with high reliability
◆ With constant temperature control system, it is not affected by ambient temperature
Air Quality Monitoring Micro Station – Atmospheric Grid Automatic Monitoring System Quotation – Product Selection Table
element | WES300-C | WES310-C | WES312-C | WES313-C | WES800-C | WES900-C | WES606-C | WES916-C | WES918-C |
CO | ● | ● | ● | ● | ● | ||||
NO | ● | ||||||||
NO2 | ● | ● | ● | ● | ● | ||||
SO2 | ● | ● | ● | ● | ● | ||||
O3 | ● | ● | ● | ● | ● | ||||
H2S | ● | ● | |||||||
NH3 | ● | ||||||||
HCL | ● | ||||||||
VOC | ● | ● | |||||||
PM2.5 | ● | ● | ● | ● | ● | ||||
PM10 | ● | ● | ● | ● | ● | ||||
noise | ● | ● | |||||||
temperature | ● | ● | ● | ● | ● | ● | ● | ● | ● |
humidity | ● | ● | ● | ● | ● | ● | ● | ● | ● |
Wind | ● | ● | ● | ● | |||||
wind velocity | ● | ● | ● | ● | |||||
atmospheric pressure | ● | ● | ● | ● | |||||
rainfall | ● | ● | ● | ||||||
radiation | ● | ● | |||||||
ultraviolet | ● | ● | |||||||
Optional functions: GPRS-a01, GPS-b02, battery-d01. |
Air Quality Monitoring Micro Station – Atmospheric Grid Automatic Monitoring System Quote – Product Parameters
Measurement parameters | Detection range | Limit of detection | Measuring principle |
CO | 0 ~ 1000ppm | 0.1ppm | electrochemistry |
NO | 0 ~ 20ppm | 5ppb | electrochemistry |
NO2 | 0 ~ 20ppm | 5ppb | electrochemistry |
SO2 | 0 ~ 100ppm | 5ppb | electrochemistry |
H2S | 0 ~ 100ppm | 1ppb | electrochemistry |
O3 | 0 ~ 20ppm | 5ppb | electrochemistry |
VOC | 0 ~ 100ppm | 5ppb | PID |
Measurement parameters | Measuring range | resolution | precision |
temperature | -40℃ ~ +60℃ | 0.1℃ | ±0.3℃ |
humidity | 0% ~ 100%Rh | 1%Rh | ±2%Rh |
Wind | 0 ~ 360° | 1° | ±3° |
wind velocity | 0~60m/s | 0.1m/s | ±0.3m/s |
atmospheric pressure | 10~1300hPa | 0.1hPa | ±0.3 hPa at 25°C) |
rainfall | 0~5mm/min | 0.1mm | ±5% |
radiation | 0~2000w/m2 | 1w/m2 | ±5% |
ultraviolet | Level 0~15 | Level 1 | ± level 1 |
Pm2.5/10 | 0 ~ 1000μg/m3 | 0.3μg/m3 | ±10μg/m3 |
noise | 30 ~ 130dB | A-weighting (simulated human ear) | ±1.5dB |
Air Quality Monitoring Micro Station – Atmospheric Grid Automatic Monitoring System Quotation – System Indicators
Input voltage : AC220
Degree of protection: IP66
Operating conditions : -40°C ~ +60°C
Signal output: RS485, RS232, Ethernet, GPRS wireless transmission optional
Air Quality Monitoring Micro Station – Atmospheric Grid Automatic Monitoring System Quotation – Application Case
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.