Atmospheric Grid Monitoring System – Four Parameters
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
- Mall catalog number: TS WES800
- Brand: Tsingsense
- Operating temperature: -40°C~+60°C
- Operating humidity: 0%~100%Rh
- Signal output: 485
- Expansion: 232
- Operating voltage: 9V
The product can be customized according to customer needs, please contact customer service or sales to provide the sensor configuration you need
For pricing, please consult customer service or sales contact number: 400-801-6230
With the development of smart technology, China’s monitoring of the ecological environment based on atmosphere, water quality and soil has been further improved, with the Internet, big data and smart environmental protection as the foundation
Basic environmental grid monitoring and management is one of the important development directions. A series of atmospheric grid monitoring systems launched by Tianxing Zhilian are mainly aimed at sensitive areas and heavy areas
A variety of environmental monitoring objects such as industrial enterprises, construction sites, and road traffic are distributed through large-density monitoring grids to monitor the dynamic changes of major pollutants in the area in real time.
Quickly capture the abnormal emission behavior of pollution sources, achieve real-time early warning, and provide scientific big data assessment for accurate haze control, so as to improve the supervision capacity and water of air pollution prevention and control
Flat.
Atmospheric Grid Monitoring System – Four-parameter Atmospheric Environment Grid Monitoring Station Product Introduction
WES series atmospheric grid air quality monitoring sensor is an online multi-parameter monitoring instrument for air quality developed and produced by our company, which can realize the presence of regional air quality
Line monitoring, which can monitor CO, SO2, NO2, O3, H2S, NO, TVOC, PM2.5/10, noise, temperature and humidity in the ambient air in all weather, continuous and automatic monitoring
Meteorological factors such as air pressure, wind speed and direction, rainfall, ultraviolet rays, and radiation. The monitoring data is transmitted to the data terminal wirelessly to grasp the change of air gas concentration in real time
Provide accurate data and scientific basis for environmental decision-making, environmental management and pollution prevention and control of environmental protection departments.
Atmospheric Grid Monitoring System – Advantages of Four-parameter Atmospheric Environment Grid Monitoring Station
◆ Publicly available system protocols
◆ Maintenance-free system design, easy to install
◆ Standard RS485 output (RS232 optional).
◆ Industrial protective shell to ensure long-term field use
◆ Optional built-in electronic compass, GPRS, GPS, etc
◆ Low power consumption, especially suitable for battery-powered systems with high power consumption requirements
Atmospheric Grid Monitoring System – Four-parameter Atmospheric Environment Grid Monitoring Station Product Features
◆ Small size and light weight
◆ Maintenance-free and easy to install
◆ Low power consumption and high precision
◆ Integrated monitoring and grid pacesetter
Atmospheric Grid Monitoring System – Technical Indicators of Four-parameter Atmospheric Environment Grid Monitoring Station
Measurement parameters | Detection range | Limit of detection | Measuring principle |
NO2 | 0 – 20ppm | 5ppb | electrochemistry |
SO2 | 0 – 100ppm | 5ppb | electrochemistry |
CO | 0 – 1000ppm | 0.1ppm | electrochemistry |
O3 | 0 – 20ppm | 5ppb | electrochemistry |
Pm2.5/10 | 0 ~ 1000μg/m3 | 0.3μg/m3 | Laser scattering |
Measurement parameters | Measuring range | resolution | precision |
temperature | -40℃~+60℃ | 0.1℃ | ±0.3℃ |
humidity | 0%~100%Rh | 1%Rh | 2%Rh |
Optional features: GPRS-a01, WiFi-a02, Ethernet-a03, GPS-b02, battery-d01. |
Atmospheric Grid Monitoring System – Four-parameter Atmospheric Environment Grid Monitoring Station Matching Table
element | WES300 | WES800 | WES900 | WES918 |
VOC | ● | ● | ||
PM2.5 | ● | ● | ● | |
PM10 | ● | ● | ● | |
CO | ● | ● | ● | |
NO2 | ● | ● | ● | |
SO2 | ● | ● | ● | |
O3 | ● | ● | ● | |
H2S | ● | |||
NO | ● | |||
temperature | ● | ● | ● | ● |
humidity | ● | ● | ● | ● |
Wind | ● | ● | ||
wind velocity | ● | ● | ||
atmospheric pressure | ● | ● |
Atmospheric Grid Monitoring System – Four-parameter Atmospheric Environment Grid Monitoring Station Product Dimensions
Atmospheric Grid Monitoring System – Schematic diagram of four-parameter atmospheric environment grid monitoring station
Zhejiang Environmental Monitoring Project
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.