Continuous Air Quality Monitoring System – Suction
⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀
☎️ Contact Us for any inquiry
-
- Mall catalog number: TS WES-C
-
- Brand: Tsingsense
- Operating temperature: -40°C ~ +60°C
- Operating humidity: 0% ~ 100%Rh
- Signal output: 485
- Expansion: 232
- Operating voltage: 9V
The product can be customized according to customer needs, please contact customer service or sales to provide the sensor configuration you need, please consult the price
Customer service or sales contact number: 400-801-6230
With the rapid development of China’s economy, environmental problems are becoming more and more serious, especially China’s ecological and environmental problems, which have become the current constraints on the sustained growth of China’s economy
A critical question. In order to have a more comprehensive and accurate understanding of air quality, Tianxing Zhilian has introduced and built a pump-type air quality monitoring system, which has achieved a more impressive results
The main advantage of this system is that it is fully automatic monitoring, which can evaluate the current air quality, real-time monitoring, and respond to air quality problems for users at any time
It can make accurate prediction services for future air quality, and realize the collection, detection and analysis of air quality data.
Continuous Air Quality Monitoring System – Pump-Suction Air Quality Monitoring Micro Station Product Introduction
TS WES-C Pump-Suction Air Quality Monitoring Station is a set of automatic air quality measurement system developed and produced by Tianxing Zhilian Technology, mainly for air gas, quality feelings
The information collection and analysis provides a reference for air quality reporting, which is helpful to improve the level of air quality monitoring in China more effectively. Air quality monitoring system is available
Monitor meteorological elements such as temperature and humidity, air pressure, wind speed and direction, rainfall, radiation, ultraviolet rays, etc., and can monitor environmental elements such as CO, O3, NO2, SO2, H2S, NO, TVOC, NH3, HCL, PM2.5/10, and noise. The system realizes the automatic collection, automatic analysis and processing of air quality data, which is more straightforward
Showing the air quality of an area. It can be widely used in the monitoring of air quality in urban streets, parks, petrochemical plant areas, residential areas, ports and other places.
Air Quality Continuous Monitoring System – Pump-Suction Air Quality Monitoring Micro Station Product Features
◆ Suitable for all kinds of wild environments
◆ RS485 communication interface, standard Modbus protocol and ASCII code protocol
◆ Support extended GPRS, WIFI, Lora, NB-loT and other communication methods
◆ Pump-type sampling method, with constant temperature control system, not affected by ambient temperature
◆ The system can be continuously monitored in real time 24 hours a day, and sensors can be selected for integration according to user needs
Continuous Air Quality Monitoring System – Pump-Suction Air Quality Monitoring Micro Station Product Selection Table
element | WES300-C | WES310-C | WES312-C | WES313-C | WES800-C | WES900-C | WES606-C | WES916-C | WES918-C |
CO | ● | ● | ● | ● | ● | ||||
NO | ● | ||||||||
NO2 | ● | ● | ● | ● | ● | ||||
SO2 | ● | ● | ● | ● | ● | ||||
O3 | ● | ● | ● | ● | ● | ||||
H2S | ● | ● | |||||||
NH3 | ● | ||||||||
HCL | ● | ||||||||
VOC | ● | ● | |||||||
PM2.5 | ● | ● | ● | ● | ● | ||||
PM10 | ● | ● | ● | ● | ● | ||||
noise | ● | ● | |||||||
temperature | ● | ● | ● | ● | ● | ● | ● | ● | ● |
humidity | ● | ● | ● | ● | ● | ● | ● | ● | ● |
Wind | ● | ● | ● | ● | |||||
wind velocity | ● | ● | ● | ● | |||||
atmospheric pressure | ● | ● | ● | ● | |||||
rainfall | ● | ● | ● | ||||||
radiation | ● | ● | |||||||
ultraviolet | ● | ● | |||||||
Optional functions: GPRS-a01, GPS-b02, battery-d01. |
Continuous Air Quality Monitoring System – Pumped Air Quality Monitoring Micro Station Product Parameters
Measurement parameters | Detection range | Limit of detection | Measuring principle |
CO | 0 ~ 1000ppm | 0.1ppm | electrochemistry |
NO | 0 ~ 20ppm | 5ppb | electrochemistry |
NO2 | 0 ~ 20ppm | 5ppb | electrochemistry |
SO2 | 0 ~ 100ppm | 5ppb | electrochemistry |
H2S | 0 ~ 100ppm | 1ppb | electrochemistry |
O3 | 0 ~ 20ppm | 5ppb | electrochemistry |
VOC | 0 ~ 100ppm | 5ppb | PID |
Measurement parameters | Measuring range | resolution | precision |
temperature | -40℃ ~ +60℃ | 0.1℃ | ±0.3℃ |
humidity | 0% ~ 100%Rh | 1%Rh | ±2%Rh |
Wind | 0 ~ 360° | 1° | ±3° |
wind velocity | 0~60m/s | 0.1m/s | ±0.3m/s |
atmospheric pressure | 10~1300hPa | 0.1hPa | ±0.3 hPa at 25°C) |
rainfall | 0~5mm/min | 0.1mm | ±5% |
radiation | 0~2000w/m2 | 1w/m2 | ±5% |
ultraviolet | Level 0~15 | Level 1 | ± level 1 |
Pm2.5/10 | 0 ~ 1000μg/m3 | 0.3μg/m3 | ±10μg/m3 |
noise | 30 ~ 130dB | A-weighting (simulated human ear) | ±1.5dB |
Air Quality Continuous Monitoring System – Pump-suction air quality monitoring micro-station system indicators
Input voltage : AC220
Degree of protection: IP66
Operating conditions : -40°C ~ +60°C
Signal output: RS485, RS232, Ethernet, GPRS wireless transmission optional
Continuous Air Quality Monitoring System – Application Case of Pumped Air Quality Monitoring Micro Station
Shipping Information
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.
Know more details.
Return Policy
You may return items purchased from Meter BD Shop within 7 days of receiving the product.
To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.
Reviews
There are no reviews yet.