FL901 Open Channel Digital Logger

14 Items sold in last 3 minutes

⛟ Stock products delivery time 1-3 working days. 🔥
✈ Out-of-stock products delivery time 10-20 working days. 🚀

☎️ Contact Us for any inquiry

18 People watching this product now!
Description

The FL900 is designed to reduce monitoring costs, increase efficiency, and provide better data 24/7 with less hassle
than you ever thought possible.

The FL901 Flow Logger with 1 sensor port provides users with a reliable, budget saving solution for open channel portable flow monitoring applications. The robust logger´s time-saving features will drastically decrease site time and increase safety for monitoring crews. The Logger LED provides instant communication verification of correct site set-up and flow meter communication prior to leaving the site. With the time saving features designed into the FL900 Flow Loggers, crews spend less time in the manhole and less time on site to decrease monitoring costs while increasing the safety of flow monitoring crews. Reduce site visits to change batteries with FL900´s long battery life. The estimated battery life at 15 minute intervals is 185 days for the Flo-Dar sensor and 306 days for the Flo-Tote 3 sensor. The logger can be quickly attached to a wall, pole or manhole ladder in minutes. Users can choose to hang logger from standard carabiner or optional 4-bolt wall mount for pole, horizontal or vertical wall mount or ladder rung mount. Municipal Applications: Sanitary Sewer Evaluation Studies, Collection Systems, Capacity Studies, Combined Sewer Overflows, Inflow and Infiltration (I & I) Studies, Billing/Custody Transfer, Plant Influent and Effluent. Industrial Apllications: Process Waste, Plant Influent, Plant Effluent, Non-contact Cooling Water, Stormwater Monitoring and Compliance.


Benefits

Reliable, Budget-Saving Monitoring

The FL900 Flow Logger provides users with a reliable, budget saving solution for open channel portable flow monitoring applications. The robust logger’s time-saving features will drastically decrease site time and increase safety for monitoring crews. The Logger LED provides instant communication verification of correct site set-up and flow meter communication prior to leaving the site.

Increase Monitoring Crew Safety

With the time saving features designed into the FL900 Flow Loggers, crews spend less time in the manhole and less time on site to decrease monitoring costs while increasing the safety of flow monitoring crews.

Long Battery Life

Reduce site visits to change batteries with FL900’s long battery life. The estimated battery life at 15 minute intervals is 185 days for the Flo-Dar sensor and 306 days for the Flo-Tote 3 sensor

Easy Installation/Versatile Mounting Options

The logger can be quickly attached to a wall, pole or manhole ladder in minutes. Users can choose to hang logger from standard carabiner or optional 4-bolt wall mount for pole, horizontal or vertical wall mount or ladder rung mount.

Plug and Play Sensor Ports

The FL900 Series Flow Logger is available with 1 sensor port. The logger auto-detects the type of sensor connected to allow customers maximum flexibility for their Hach flow sensor inventories.

Specifications

Technical Attributes

Accuracy Timebase Accuracy: +/- 0.002 % , synchronized every 24 hours with server software and modem
Alarm 16 maximum
Alarm Actions Send an e-mail, or send text message (SMS) (requires wireless logger and active wireless service), trigger sampler, change logging interval, change call interval
Battery Life 306 days With Flo-Tote Sensor (no modem, room temperature) @ 15 minute logging intervals
Cellular None
Certifications Logger: CE, optional AC power supply: UL/CSA/CE
Communication USB RS232 (Baud rates: 9600, 19200, 38400, 57600, 115200)
Communication (optional) Remote Communications (optional): Wireless modem: 3G & 4G LTE
Connector 1 Stainless steel connectors
Data Storage Datalog: 325,000 sensor measurement data points; 1128 days for 3 channels at 15-minute log intervals
Event Log: 1,000 events maximum in non-volatile flash memory
Sample History: 2,000 sample events maximum in non-volatile flash memory
Data Storage 2 Sample History: 2000 sample events maximum in non-volatile flash memory
Data Storage 3 Datalog: 325 k data points, 1128 days for 3 channels at 15-minute log intervals
Datalog Channels 16 maximum
Dimensions 25.4 x 22 x 40 cm
(10.0 x 8.7 x 16.0 in.)
Enclosure Construction PC/ABS structural foam
Environmental Rating NEMA 6P (IP68)
Interface Hach AS950 Automatic Sampler
All Hach legacy samplers
Non-Hach samplers capable of being triggered by 5 V dc pulse lasting 50 milliseconds
Internet Application Software FSDATA web-based software for flowmeter programming, data management and report generation for wireless flow meters
LED Status Indicator • Green Flashes every 3 sec during normal operation. Flashes every 15 sec during sleep mode.
• Red Flashes when attached sensor does not agree with the logger program, when an expected sensor is not found or the sensor is not working properly.
Length 254 mm (25.4 cm)
Logging Intervals 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 or 60 minutes
Primary and secondary intervals for dynamic logging.
Manual Languages English
Modem Non-Wireless
Operating Temperature Range -18 to 60ºC (0 to 140ºF) at 95% RH
PC Data Transfer Software FSDATA Desktop Instrument Manager software required for programmig logger. Can be used for data management and report generation. It is compatible with desktop/lap top computers utilizing Windows operating system. Minimum resolution: 1024×768.
Power Requirements (Voltage) 8 – 18 V DC
Protocol Modbus RTU
Modbus ASCII
Mobile-Terminated SMS
Mobile-Originated SMS
TCP/IP
Rain Gauge Enabled No
Sensor Connector 1
Sensor Connectors 1, additional options
Sensor Ports 1, 2, or 4
Special Remarks When paired with a Hach sampler, successful or failed sample, as well as bottle number, are stored in sample history. Sample history can be included in reports generated by FSDATA.
Standard storage temperature -40 to 60ºC (-40 to 140ºF)
Storage Conditions -40 °F to 140 °F
Supported Sensors Flo-Dar, Flo-Dar with SVS, Flo-Tote, Rain Guage
Warranty 12 months
Weight Using Model FL900:
4.5 kg (10 lb)—no batteries;
6.3 kg (14 lb)—2 batteries;
8.2 kg (18 lb)—4 batteries
Shipping & Returns Policy

Shipping Information

Dhaka Only: Same-day or next-day delivery within Dhaka city limits and cost only ৳80 TAKA.
Out Of Dhaka: 1–3 working days for most locations within Bangladesh and cost only ৳120 TAKA.

Know more details. 

Return Policy

You may return items purchased from Meter BD Shop within 7 days of receiving the product.

To be eligible for a return, the product must meet the following conditions:
1. Unused, 2. In the original packaging & 3. Proof of purchase.

Read More

Reviews

There are no reviews yet.

Be the first to review “FL901 Open Channel Digital Logger”

Your email address will not be published. Required fields are marked *