Used for testing the color fastness-to-light, color fastness-to-weather of various colored textiles in color
fastness experiments and also for the testing of the color fastness-to-light, light aging of paint, pigment,
coating, rubber, plastic, wood floor, paper and other materials.
fastness experiments and also for the testing of the color fastness-to-light, light aging of paint, pigment,
coating, rubber, plastic, wood floor, paper and other materials.
Relevant Standards
GB/T8427(national standards technical committees)
GB/T14576, GB/T15102-2006, GB/T15104-2006, GB/T8430, AATCC TM16, ISO105-B04, ISO105-B02
GB/T8427(national standards technical committees)
GB/T14576, GB/T15102-2006, GB/T15104-2006, GB/T8430, AATCC TM16, ISO105-B04, ISO105-B02
Instrument characteristics
1.Extra large test chamber design and large size sample hanging rail max
2.Digital setting of light intensity, real-time monitoring and automatic adjustment to meet different
standards for testing the stability of light source (420nm, 340nm or from 300nm to 400nm waved band
monitor optional)
3.The sample is tested with black plate thermometer ( BPT ),black plate standard thermometer (BST),
irradiance detector at the same position (in equidistance) to really indicate measuring state of the sample,
the tested data is transmitted synchronously by using technology of radio frequency and indicated on the
color screen in the forms of digit, chart, curve, etc. after CPU process, without shutdown for observation.
4.Test and radio transmission are powered by using light conversion technology, no additional power
supply is required
5.10.4 inch color touching screen display control and various test monitoring modules (animation, digit,
chart) make operation easy, visual and clear
6. With parallel communication interface for print out of A4 sized paper
1.Extra large test chamber design and large size sample hanging rail max
2.Digital setting of light intensity, real-time monitoring and automatic adjustment to meet different
standards for testing the stability of light source (420nm, 340nm or from 300nm to 400nm waved band
monitor optional)
3.The sample is tested with black plate thermometer ( BPT ),black plate standard thermometer (BST),
irradiance detector at the same position (in equidistance) to really indicate measuring state of the sample,
the tested data is transmitted synchronously by using technology of radio frequency and indicated on the
color screen in the forms of digit, chart, curve, etc. after CPU process, without shutdown for observation.
4.Test and radio transmission are powered by using light conversion technology, no additional power
supply is required
5.10.4 inch color touching screen display control and various test monitoring modules (animation, digit,
chart) make operation easy, visual and clear
6. With parallel communication interface for print out of A4 sized paper
7. Individual timing of each sample clamp may enable different sample test in a same tester and facilitate
test monitor and reduce operation cost
8. specialty long-arc xenon lamp technology adopted to real simulate sunlight spectrum
9. With industrial temperature control (refrigeration) system for smoothly and fast adjusting temperature in
test chamber
10. Ultrasonic humidification and professional dehumidification system guarantee the accuracy and
stability of testing humidity
11. Natural circulation system and air filter system inside reduces the environmental requirements greatly
12. One test can run for 1000 hour continuously with quality guarantee
Technical parameters
test monitor and reduce operation cost
8. specialty long-arc xenon lamp technology adopted to real simulate sunlight spectrum
9. With industrial temperature control (refrigeration) system for smoothly and fast adjusting temperature in
test chamber
10. Ultrasonic humidification and professional dehumidification system guarantee the accuracy and
stability of testing humidity
11. Natural circulation system and air filter system inside reduces the environmental requirements greatly
12. One test can run for 1000 hour continuously with quality guarantee
Technical parameters
Test compartment temperature control
|
30~50℃, Resolution: 0.1 ℃
|
Storage humidity control test
|
Light condition:10-65% RH, humidity fluctuations ±3%RH;
Dark condition:40-95% RH, humidity fluctuate ± 5% RH; |
Time control experiments
|
0min~999:59h, Accuracy ± 1min
|
Irradiance control
|
1-1.5W/m2/420nm Accuracy: ± 0.03W/m2/420nm; digital set,
automatic compensation |
Control and monitoring wavelength
|
Optional 340nm, 420nm ,300-400nm ,300-800nm,
|
Xenon arc lamp rated power
|
3.5KW
|
Sample holder rotation speed
|
5rpm
|
Maximum exposure area
|
1170cm2
|
Sample holder can be mounted with the
number of dimensions |
145 × 75mm model 18; 145 × 45mm model 26
|
Timing of each sample holder, respectively,
|
≤10000h
|
Photoperiod
|
≤10000h
|
Spray cycle
|
≤10000h
|
Blackboard temperature range
|
(BPT) 40-75℃±2℃;(BST) 45-80℃±2℃
|
Display control
|
10.4-inch touch screen
|
Data Output
|
Digital color display (A4 print in English optional)
|
Sample holder type
|
Double
|
Requirements within the recycled water
|
High water flow: 0.5L/min
|
Power supply
|
AC380V±5% 50Hz 6kW
|
Dimensions
|
1250×1000×1800mm
|
Weight
|
400kg
|